8m Dual-Height Ringlock Line Array Support Structure with 4m Ballast Tower and Steel Hanging Beam
An 8m-high modular Ringlock line array support structure consisting of two connected towers with different heights. The main tower reaches 8m and incorporates a 2.8m steel hanging beam for the speaker suspension position, while the connected 4m auxiliary tower provides a lower ballast area. A working platform is integrated at the bottom of the main tower. The complete structure occupies an approximately 2m × 4m footprint and uses modular Ringlock standards, ledgers, diagonal braces, adjustable bases, steel support components and pallet platforms.
This configuration is a temporary ground support system for a suspended line array, built from two connected Ringlock towers rather than one uniform-height scaffold framework.
The main tower is 8m high, and the auxiliary tower is 4m high. Together, they form a structure approximately 2m wide and 4m deep.
The upper portion of the main tower contains a steel horizontal beam for the line array hanging position.
At the lower level, the structure includes two separate functional areas:
A working platform at the bottom of the main tower
A ballast-support area at the bottom of the auxiliary tower
The defining feature is the combination of two different tower heights within one connected modular framework.
Instead of extending the entire 2×4m structure to 8m, this configuration retains a full-height speaker-support tower and a lower auxiliary tower.
This distinction is important when comparing different Ringlock sound tower configurations.
2. Overall Structural Configuration
Item
Confirmed Specification
Overall Footprint
Approximately 2m wide × 4m deep
Main Tower Height
8m
Auxiliary Tower Height
4m
Maximum Structural Height
8m
Main Structural System
Ringlock
Structural Arrangement
Two connected towers
Main Hanging Member
Steel horizontal beam
Steel Hanging Beam Length
2.8m
Main Function
Line array speaker suspension
Main Tower Lower Area
Working platform
Auxiliary Tower Lower Area
Ballast-support position
Packing Weight
Approximately 680kg
Packing Volume
Approximately 2CBM
Customization
Available
The 2×4m dimension refers to the complete nominal footprint, not to the footprint of each individual tower.
The precise division of the footprint between the two tower sections must follow the project drawing.
3. Structural Breakdown: Five Functional Modules
Module A — 8m Main Ringlock Tower
The main tower provides the full-height vertical framework for the speaker hanging position.
It uses 2m Ringlock standards connected by horizontal pipes and diagonal bracing.
The 8m height corresponds to four nominal 2m vertical modules.
This is a geometric description of the modular height, not a confirmation of every intermediate connection or platform level.
The main tower also includes a working-platform area at its bottom.
The upper steel beam is integrated into this main tower rather than being supported by a separate aluminum truss tower.
Module B — 4m Auxiliary Ringlock Tower
The auxiliary tower is connected to the main structure and reaches 4m high.
Its principal identified lower-level function is to provide a ballast-support area.
This is a separate Ringlock structural section, not simply a loose outrigger attached to the main tower.
The auxiliary tower shares the complete structure's overall footprint and is connected to the main tower as part of the supplied configuration.
The source does not establish the exact connection details or how forces are distributed between the two tower sections.
Module C — 2.8m Steel Hanging Beam
The upper hanging member is a steel section beam with a stated length of 2.8m.
This beam is positioned above the main tower and provides the intended line array suspension interface.
The configuration is therefore different from a speaker tower using a CS40 aluminum square truss or a projecting suspended scaffold section.
The steel beam is a separate functional component of the Ringlock support structure.
The actual hanging point, connection method and allowable speaker load must be verified for the intended equipment.
Module D — Lower Working Platform
The source identifies a working platform at the bottom of the main tower.
The BOQ contains nine pallet components in total.
The working platform provides a practical area associated with installation and equipment access.
It should not be interpreted as a high-level maintenance deck or multiple elevated working floors.
The exact number of pallets assigned to the main working platform is not separately identified.
Module E — Auxiliary Ballast Area
The lower portion of the 4m auxiliary tower provides a designated ballast position.
This is one of the main reasons the complete configuration has a second, shorter tower.
The structural concept separates the upper speaker suspension function from the lower ballast-placement function.
However, the published configuration does not establish a required ballast mass, tank size, water quantity or anchoring arrangement.
These must be determined from the actual installation conditions.
4. Complete Bill of Quantities (BOQ)
The following component quantities are taken from the published DragonTruss configuration.
No.
Component
Specification
Quantity
1
Horizontal Pipe
L = 2m
29 pcs
2
Diagonal Pipe LR3
L = 2.44m
24 pcs
3
Pillar / Vertical Standard LR1
L = 2m
20 pcs
4
Adjustable Base LR4
H = 0.25m
6 pcs
5
Steel Brace
L = 2m, H = 0.25m
5 pcs
6
Steel Section Beam
L = 2.8m
1 pc
7
Pallet
Platform component; individual dimensions not specified
The main tower continues upward toward the speaker hanging position.
The auxiliary tower does not extend to the same height.
Lower Zone: 0–4m
Both tower sections occupy the lower structural zone.
The main tower contains the lower working-platform area, while the auxiliary tower contains the ballast-support position.
This is the key visual and functional difference from a uniform-height tower.
It is also different from a single 8m tower with only a short 2m auxiliary base.
The height relationship can be expressed as:
Full-Height Sound Support + Lower Auxiliary Ballast Structure
This is a useful way to understand the configuration when preparing drawings, component lists or alternative proposals.
7. The Steel Beam Suspension Interface
The 2.8m steel section beam is the dedicated upper hanging member.
This creates a simple division of functions:
Ringlock Main Tower → Steel Hanging Beam → Line Array Suspension Position
The Ringlock structure provides the main tower framework.
The steel beam provides the equipment hanging interface.
The actual structural load path depends on the beam supports, connections, speaker position and complete system configuration.
No allowable suspended load is established by the published BOQ.
The presence of a 2.8m beam should not be interpreted as a confirmed clear span, effective cantilever length or rated lifting capacity.
8. Working Platform and Ballast Position: Two Different Functions
The original structure contains both a working platform and a ballast-support position.
These should remain separate in the structural breakdown.
Area
Location
Intended Function
Working Platform
Bottom of 8m main tower
Installation and equipment access
Ballast Position
Bottom of 4m auxiliary tower
Ballast placement
Hanging Beam
Top of 8m main tower
Line array suspension
The nine pallets form part of the lower platform arrangement.
However, the exact distribution between the two lower areas is not specified.
It would be incorrect to assign a fixed number of pallets to either area without the detailed layout.
Similarly, a designated ballast position does not confirm the actual stabilization requirement.
The complete ballast arrangement must be reviewed using the equipment weight, tower geometry, wind conditions, ground conditions and any specified anchoring method.
9. Difference from a Single-Tower Ringlock PA Structure
A conventional single-tower sound support may use one primary vertical framework with a hanging member at the top.
This dual-height configuration introduces a connected lower auxiliary tower.
The difference is not merely an additional quantity of Ringlock components.
It changes the arrangement of the lower structural zones.
The auxiliary section has its own height and functional ballast area, while the main section continues to the speaker hanging position.
That reference uses a shorter auxiliary base, making it a useful comparison with the present 4m auxiliary tower.
10. Difference from the 8m Ringlock Tower with Aluminum Truss
Another 8m Ringlock PA configuration uses an aluminum truss suspension system and additional equipment-support platforms.
The present structure is different in three important ways.
First, its main hanging member is a 2.8m steel section beam, not a CS40 aluminum square truss.
Second, its lower structural geometry is defined by an 8m main tower and 4m auxiliary tower.
Third, its working platform and ballast area are associated with two connected tower sections rather than the multi-function aluminum-truss arrangement.
These configurations should be analyzed as different structural products, not merely variations of the same product name.
This distinction matters when interpreting reference drawings: a lower auxiliary tower and an upper suspended scaffold part are not the same structural feature.
13. General Modular Assembly Logic
The structure can be understood through the following modular sequence:
Establish the overall 2×4m footprint using the approved project layout.
Position the six adjustable bases at the specified support points.
Assemble the lower connected Ringlock framework using vertical standards and horizontal members.
Install the diagonal members and additional steel braces according to the drawing.
Continue the main tower toward its 8m overall height.
Complete the auxiliary tower at its 4m overall height.
Integrate the lower working-platform and ballast-support areas.
Install the 2.8m steel hanging beam at the specified upper position.
Complete the required rigging, access, stabilization and structural verification before suspending equipment.
This sequence explains the modular relationship of the components.
It is not a substitute for an approved installation method, lifting plan or structural drawing.
14. Typical Applications
This dual-height Ringlock audio tower may be considered for:
Concert line array suspension
Festival PA support
Outdoor live-event sound systems
Temporary event sound towers
Rental-company speaker support installations
Church and worship events
Touring audio applications requiring a modular ground-support structure
For the wider category of temporary speaker and PA support structures, visit Sound Support Structure.
15. What Changes When the Requirements Change?
The published 2×4×8m arrangement is one reference configuration.
A customized proposal may require changes to the main tower height, auxiliary tower height, footprint, steel hanging beam, platform layout, ballast-support area or rigging interface.
The most important variables are the suspended speaker system and the installation site.
For example, changing the required speaker hanging height changes the main tower geometry.
Changing the auxiliary tower height changes the relationship between the two connected sections.
Changing the speaker model or hanging position may affect the required beam and connection arrangement.
Changing the installation site may affect the ballast, anchoring and ground-support requirements.
These changes should be reflected in the revised drawing and BOQ rather than treated as simple dimensional substitutions.
16. Information Required for a Similar Tower
To prepare a customized structural proposal, customers should provide:
Speaker manufacturer and model
Number of line array cabinets
Total suspended equipment weight
Required hanging height
Intended speaker hanging position
Required overall footprint
Available space behind the speaker position
Working-platform requirements
Indoor or outdoor application
Event location
Ground conditions
Ballast or anchoring constraints
Existing Ringlock components, if any
Reference drawings or site photographs
A quotation can begin with a reference structure, but the final configuration must reflect the actual equipment and site conditions.
17. Engineering and Verification Boundary
The original product confirms the following:
Two connected Ringlock towers
8m main tower
4m auxiliary tower
Approximately 2×4m footprint
2.8m steel hanging beam
Lower working platform
Auxiliary ballast-support position
Published component quantities
Approximate packing weight and volume
The original product does not establish:
Maximum allowable line array weight
Steel hanging beam load capacity
Rated hanging-point capacity
Platform load capacity
Required ballast weight
Wind resistance
Anchoring or foundation requirements
Ground-bearing capacity
Safety factors
Certification or engineering approval
The approximately 680kg packing weight is a shipping figure, not a suspended-load rating.
The complete configuration requires project-specific engineering and rigging verification before use.
18. Related Structural Application
A line array tower may also form part of a larger concert structure that includes a main stage, roof, LED support areas and other technical equipment.
However, its relationship to the wider stage system must be established through the actual project layout.
The original listing is the recommended purchasing and quotation reference. Pricing and the final supply scope should be confirmed against the required project configuration.
Frequently Asked Questions
1. What is the overall size of this Ringlock line array structure?
The complete footprint is approximately 2m wide and 4m deep. The main tower reaches 8m, while the connected auxiliary tower reaches 4m.
2. Why does the structure have two different tower heights?
The main tower provides the upper speaker hanging position. The lower auxiliary tower forms an additional connected structural section with a designated ballast-support area.
3. Is the auxiliary tower a separate freestanding tower?
No. The published configuration describes two connected Ringlock towers forming one system.
4. What is used to hang the line array?
A 2.8m steel section beam is installed above the main tower as the intended hanging member.
5. Does this structure use aluminum truss for the main hanging beam?
No aluminum truss is listed in the published BOQ. The identified upper hanging member is steel.
6. How many Ringlock vertical standards are included?
The complete package includes 20 vertical standards, each 2m long.
7. How many diagonal pipes are included?
The BOQ includes 24 diagonal pipes with a stated length of 2.44m.
8. What is the working platform used for?
The working platform at the bottom of the main tower is intended for installation and access-related work.
9. How many pallets are included?
Nine pallet components are listed in the BOQ. Their exact distribution between the lower platform areas is not specified.
10. Is ballast included in the package?
The structure includes a designated ballast-support position. The source does not separately identify a supplied ballast mass or water-tank quantity.
11. What is the maximum speaker weight?
The published product information does not provide a verified allowable suspended load. This must be established for the actual speaker and structural arrangement.
12. Can the 4m auxiliary tower be made taller?
Customization is available, but changing the auxiliary height requires a revised structural configuration and verification.
13. Is the structure suitable for outdoor concerts?
It is intended for temporary concert and event sound-support applications. Actual outdoor suitability depends on wind, loading, ground conditions and the verified stabilization arrangement.
14. How much does the structure weigh for shipping?
The published approximate packing weight is 680kg, with a packing volume of about 2CBM.
Why Rental Companies Put Ground-Supported LED Walls on Stage Risers—and What We Check Before Recommending It
Why Rental Companies Put Ground-Supported LED Walls on Stage Risers—and What We Check Before Recommending ItProject BackgroundThis case analysis started from a public discussion in the video-engineering industry.The question was simple:Why are more ground-supported LED walls being installed on stage
2026-10-30
How We Turned Standard Stage Stairs into a Movable Indoor Venue Entrance System
How We Turned Standard Stage Stairs into a Movable Indoor Venue Entrance SystemProject BackgroundThis project came from an indoor sports and event venue in the Americas.For confidentiality reasons, we do not identify the country or whether the venue is located in North or South America.The venue had
2026-11-13
Why We Use Pivoting Adjustable Stairs Between Different Stage Heights
Why We Use Pivoting Adjustable Stairs Between Different Stage HeightsProject BackgroundA common question in temporary stage systems is:Can one stair unit be used with different stage heights?At first, this sounds like a simple compatibility question.But from a stage manufacturer's point of view, the
2026-11-06
Why a Single Clamped Tube Can Make an LED Wall Difficult to Keep Vertical
Why a Single Clamped Tube Can Make an LED Wall Difficult to Keep VerticalProject BackgroundThis case analysis started from a public video-engineering discussion.The user needed to mount LED panels onto a truss structure.The tested solution used:a single horizontal tube;O-clamps / tube clamps;LED mod
2026-10-17
Why We Split Large Custom Bar Truss Structures After the Overall Design Is Approved
Why We Design Large Custom Bar Truss as One Structure First—and Then Split It for Production and Site AccessProject BackgroundMany of our custom aluminum-truss projects for bars, clubs and entertainment venues begin with the same contradiction.The venue owner or design team wants a large, visually c
Why Rental Companies Put Ground-Supported LED Walls on Stage Risers—and What We Check Before Recommending It
Why Rental Companies Put Ground-Supported LED Walls on Stage Risers—and What We Check Before Recommending ItProject BackgroundThis case analysis started from a public discussion in the video-engineering industry.The question was simple:Why are more ground-supported LED walls being installed on stage
2026-10-30
How We Turned Standard Stage Stairs into a Movable Indoor Venue Entrance System
How We Turned Standard Stage Stairs into a Movable Indoor Venue Entrance SystemProject BackgroundThis project came from an indoor sports and event venue in the Americas.For confidentiality reasons, we do not identify the country or whether the venue is located in North or South America.The venue had
2026-10-30
Why We Use Pivoting Adjustable Stairs Between Different Stage Heights
Why We Use Pivoting Adjustable Stairs Between Different Stage HeightsProject BackgroundA common question in temporary stage systems is:Can one stair unit be used with different stage heights?At first, this sounds like a simple compatibility question.But from a stage manufacturer's point of view, the
2026-11-13
Why a Single Clamped Tube Can Make an LED Wall Difficult to Keep Vertical
Why a Single Clamped Tube Can Make an LED Wall Difficult to Keep VerticalProject BackgroundThis case analysis started from a public video-engineering discussion.The user needed to mount LED panels onto a truss structure.The tested solution used:a single horizontal tube;O-clamps / tube clamps;LED mod
2026-11-06
Why We Split Large Custom Bar Truss Structures After the Overall Design Is Approved
Why We Design Large Custom Bar Truss as One Structure First—and Then Split It for Production and Site AccessProject BackgroundMany of our custom aluminum-truss projects for bars, clubs and entertainment venues begin with the same contradiction.The venue owner or design team wants a large, visually c
DragonStructure is a specialized platform created to explore modular temporary structures, structural applications and system integration for events and other professional temporary-structure projects.